Skip to the content.

Relion: Refine your volume

  1. From the .tbl files of the 2 half-steps in the previous step, generate a .star file:
     conda activate tomotools
     python convert_tbl_to_warp.py \
     -r $ROOT/warp \
     -t1 dynamo/dynamo_project_b4/abp_align_eo/results/ite_0004/averages/refined_table_ref_001_ite_0004.tbl \
     -t2 dynamo/dynamo_project_b4/abp_align_eo/results/ite_0004/averages/refined_table_ref_002_ite_0004.tbl \
     -w particles_dynamo_b4.star \
     -o particles_dynamo_b2.star \
     -a $ANGPIX \
     -tm dynamo/particles_b4.reextract.doc \
     -b 4 # binning of the .tbl files (was bin4)
    

Extract particles at bin4 for Relion

  1. Use this star file to re-extract particles with warp:

     # Compute box diameter (floor)
     BOXDIM=$(awk "BEGIN { print int($ANGPIX_BIN4 * $BOXSIZE) }")
     # Export particles
     cd $ROOT/warp
     WarpTools ts_export_particles \
     --settings warp_tiltseries.settings \
     --input_star particles_dynamo_b2.star \
     --output_star relion5_b4/Extract/bin4_box$BOXSIZE/particles.star \
     --coords_angpix $ANGPIX \
     --output_angpix $ANGPIX_BIN4 \
     --box $BOXSIZE \
     --diameter $BOXDIM \
     --relative_output_paths \
     --2d \
     --output_processing relion5_b4/Extract/bin4_box$BOXSIZE/
    
  2. To do helical processing, Relion5 expects a _rnlAngleTilt of 90. The script warp_to_relion5.py rotates the Euler angle of the subtomograms such that _rnlAngleTilt is 90. Also, it converts the coordinates to be compatible with Relion5 (in Angstroms and measured from the center of the tomogram).
     cd $REPOSITORY
     python warp_to_relion5.py \
     --relionroot $ROOT/warp/relion5_b4 \
     --prestar ../particles_dynamo_b2.star \
     --poststar Extract/bin4_box$BOXSIZE/particles.star \
     --tomo Extract/bin4_box$BOXSIZE/particles_tomograms.star \
     --out Extract/bin4_box$BOXSIZE/particles_relion5_tiltprior90.star \
     --bin 4 \
     --tiltprior90
    
  3. Rescale one of the two halfmaps from dynamo bin4 to bin2. First, convert one of the halfmaps to an mrc file:
     cd $ROOT/warp
     ANGPIX_BIN4=$(echo "$ANGPIX * 4" | bc)
     e2proc3d.py --mult=-1 dynamo/dynamo_project_b4/abp_align_eo/results/ite_0004/averages/average_ref_001_ite_0004.em dynamo_bin4_ite4.mrc
     relion_image_handler --i dynamo_bin4_ite4.mrc --o dynamo_bin4_ite4.mrc --force_header_angpix $ANGPIX_BIN4
    

    Then, search the symmetry:

    relion_helix_toolbox --i dynamo_bin4_ite4.mrc --twist_min 1 --twist_max 1.9 --rise_min 4.6 --rise_max 4.8 --z_percentage 0.3 --search --cyl_outer_diameter 200 --angpix $ANGPIX_BIN4

    Below, set the twist and rise to the optima found above:

    # Apply symmetry
    relion_helix_toolbox --i dynamo_bin4_ite4.mrc --twist 1.09 --rise 4.8 --z_percentage 0.3 --impose --cyl_outer_diameter 180 --angpix $ANGPIX_BIN4 --o dynamo_bin4_ite4_sym.mrc

    The output is already at bin4.

Extract particles at bin2

  1. Use this star file to re-extract particles with warp:

     # Compute box diameter (floor)
     BOXDIM=$(awk "BEGIN { print int($ANGPIX_BIN2 * $BOXSIZE) }")
     # Export particles
     cd $ROOT/warp
     WarpTools ts_export_particles \
     --settings warp_tiltseries.settings \
     --input_star particles_dynamo_b2.star \
     --output_star relion5_b2/Extract/bin2_box$BOXSIZE/particles.star \
     --coords_angpix $ANGPIX \
     --output_angpix $ANGPIX_BIN2 \
     --box $BOXSIZE \
     --diameter $BOXDIM \
     --relative_output_paths \
     --2d \
     --output_processing relion5_b2/Extract/bin2_box$BOXSIZE/
    
  2. To do helical processing, Relion5 expects a _rnlAngleTilt of 90. The script warp_to_relion5.py rotates the Euler angle of the subtomograms such that _rnlAngleTilt is 90. Also, it converts the coordinates to be compatible with Relion5 (in Angstroms and measured from the center of the tomogram).
     cd $REPOSITORY
     python warp_to_relion5.py \
     --relionroot $ROOT/warp/relion5_b2 \
     --warp ../particles_dynamo_b2.star \
     --relion Extract/bin2_box$BOXSIZE/particles.star \
     --tomo Extract/bin2_box$BOXSIZE/particles_tomograms.star \
     --out Extract/bin2_box$BOXSIZE/particles_rot90.star
    
  3. Rescale one of the two halfmaps from dynamo bin4 to bin2. First, convert one of the halfmaps to an mrc file:
     cd $ROOT/warp
     ANGPIX_BIN4=$(echo "$ANGPIX * 4" | bc)
     ANGPIX_BIN2=$(echo "$ANGPIX * 2" | bc)
     e2proc3d.py --mult=-1 dynamo/dynamo_project_b4/abp_align_eo/results/ite_0004/averages/average_ref_001_ite_0004.em dynamo_bin4_ite4.mrc
     relion_image_handler --i dynamo_bin4_ite4.mrc --o dynamo_bin4_ite4.mrc --force_header_angpix $ANGPIX_BIN4
    
    relion_helix_toolbox --i dynamo_bin4_ite4.mrc --twist_min 1 --twist_max 1.9 --rise_min 4.6 --rise_max 4.8 --z_percentage 0.3 --search --cyl_outer_diameter 200 --angpix $ANGPIX_BIN4

    Below, set the twist and rise to the optima found above:

    # Apply symmetry
    relion_helix_toolbox --i dynamo_bin4_ite4.mrc --twist 1.09 --rise 4.8 --z_percentage 0.3 --impose --cyl_outer_diameter 180 --angpix $ANGPIX_BIN4 --o dynamo_bin4_ite4_sym.mrc
     # Rescale to the new pixel size
     relion_image_handler --i dynamo_bin4_ite4_sym.mrc --o relion5_b2/dynamo_bin2_ite4_sym_box$BOXSIZE.mrc --angpix $ANGPIX_BIN4 --rescale_angpix $ANGPIX_BIN2 --new_box $BOXSIZE --force_header_angpix $ANGPIX_BIN2
    

Extract particles at bin 1

  1. Use this star file to re-extract particles with warp:

     # Set boxsize for extraction at bin 1
     BOXSIZE_BIN1=128
     BOXDIM=$(awk "BEGIN { print int($ANGPIX * $BOXSIZE_BIN1) }")
     # Export particles
     cd $ROOT/warp
     WarpTools ts_export_particles \
     --settings warp_tiltseries.settings \
     --input_star particles_dynamo_b2.star \
     --output_star relion5_b1/Extract/bin1_box$BOXSIZE_BIN1/particles.star \
     --coords_angpix $ANGPIX \
     --output_angpix $ANGPIX \
     --box $BOXSIZE_BIN1 \
     --diameter $BOXDIM \
     --relative_output_paths \
     --2d \
     --output_processing relion5_b1/Extract/bin1_box$BOXSIZE_BIN1/
    
  2. To do helical processing, Relion5 expects a _rnlAngleTilt of 90. The script warp_to_relion5.py rotates the Euler angle of the subtomograms such that _rnlAngleTilt is 90. Also, it converts the coordinates to be compatible with Relion5 (in Angstroms and measured from the center of the tomogram).
     cd $REPOSITORY
     python warp_to_relion5.py \
     --relionroot $ROOT/warp/relion5_b1 \
     --warp ../particles_dynamo_b2.star \
     --relion Extract/bin1_box$BOXSIZE_BIN1/particles.star \
     --tomo Extract/bin1_box$BOXSIZE_BIN1/particles_tomograms.star \
     --out Extract/bin1_box$BOXSIZE_BIN1/particles_rot90.star
    
  3. Rescale one of the two halfmaps from dynamo bin4 to bin1. First, convert one of the halfmaps to an mrc file:
     cd $ROOT/warp
     ANGPIX_BIN4=$(echo "$ANGPIX * 4" | bc)
     # Rescale to the new pixel size
     relion_image_handler --i dynamo_bin4_ite4_sym.mrc --o relion5_b1/dynamo_bin1_ite4_sym_box$BOXSIZE_BIN1.mrc --angpix $ANGPIX_BIN4 --rescale_angpix $ANGPIX --new_box $BOXSIZE_BIN1 --force_header_angpix $ANGPIX
    

Generate a mask

relion_helix_toolbox --o mask.mrc --cyl_outer_diameter 200 --angpix 7.92 --boxdim 64 --sphere_percentage 0.6 --cylinder

← Back | Next →